Results
Note: IBC construction types determine allowable height and area per Table 504.3 and 506.2. Type I is the most fire-resistant (noncombustible, highest ratings). Type V is the least restrictive. The classification is based on the fire-resistance ratings of structural elements.
Reference
IBC Table 601 - Fire-Resistance Rating Requirements (hours)
Type I-A: Structural=3, Bearing=3, Floor=2, Roof=1.5
Type I-B: Structural=2, Bearing=2, Floor=2, Roof=1
Type II-A: Structural=1, Bearing=1, Floor=1, Roof=1
Type II-B: Structural=0, Bearing=0, Floor=0, Roof=0 (Noncombustible)
Type III-A: Ext Bearing=2, Int=1, Floor=1, Roof=1
Type III-B: Ext Bearing=2, others=0
Type IV-HT: Heavy Timber, Structural=2/HT
Type V-A: Structural=1, Bearing=1, Floor=1, Roof=1 (Combustible)
Type V-B: No requirements (Combustible)